<?xml version="1.0" encoding="UTF-8"?>
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="JATS-archive-oasis-article1-4.xsd" article-type="research-article" dtd-version="1.4" xml:lang="ru">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Журнал Научное обозрение. Технические науки</journal-title>
      </journal-title-group>
      <issn>2500-0799</issn>
      <publisher>
        <publisher-name>Общество с ограниченной ответственностью "Издательский Дом "Академия Естествознания"</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">ART-1198</article-id>
      <title-group>
        <article-title>О ТРЕБОВАНИЯХ, ПРЕДЪЯВЛЯЕМЫХ К ПРИБОРАМ ДЛЯ ОПРЕДЕЛЕНИЯ КРИТИЧЕСКОЙ ЧАСТОТЫ СВЕТОВЫХ МЕЛЬКАНИЙ</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name-alternatives>
            <name xml:lang="ru">
              <surname>Оруджова</surname>
              <given-names>Ольга Низамиевна</given-names>
            </name>
          </name-alternatives>
          <name-alternatives>
            <name xml:lang="en">
              <surname>Orudzhova</surname>
              <given-names>O.N.</given-names>
            </name>
          </name-alternatives>
          <email>o.orudjova@narfu.ru</email>
          <xref ref-type="aff" rid="aff5c47cba0"/>
        </contrib>
        <contrib contrib-type="author">
          <name-alternatives>
            <name xml:lang="ru">
              <surname>Шабунина</surname>
              <given-names>Наталья Владимировна</given-names>
            </name>
          </name-alternatives>
          <name-alternatives>
            <name xml:lang="en">
              <surname>Shabunina</surname>
              <given-names>N.V.</given-names>
            </name>
          </name-alternatives>
          <email>n.shabunina@narfu.ru</email>
          <xref ref-type="aff" rid="aff5c47cba0"/>
        </contrib>
      </contrib-group>
      <aff id="aff5c47cba0">
        <institution xml:lang="ru">ФГАОУ ВО «Северный (Арктический) федеральный университет имени М.В. Ломоносова»</institution>
        <institution xml:lang="en">Northern (Arctic) Federal University named after M.V. Lomonosov</institution>
      </aff>
      <pub-date date-type="pub" iso-8601-date="2018-05-08">
        <day>08</day>
        <month>05</month>
        <year>2018</year>
      </pub-date>
      <issue>5</issue>
      <fpage>25</fpage>
      <lpage>29</lpage>
      <permissions>
        <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
          <license-p>This is an open-access article distributed under the terms of the CC BY 4.0 license.</license-p>
        </license>
      </permissions>
      <self-uri content-type="url" hreflang="ru">https://science-engineering.ru/ru/article/view?id=1198</self-uri>
      <abstract xml:lang="ru" lang-variant="original" lang-source="author">
        <p>В настоящее время метод критической частоты слияния мельканий (КЧСМ) достаточно широко применяется в диагностике и лечении оптической системы человека. На сегодняшний день используют множество приборов и аппаратов, предназначенных для исследования КЧСМ. При этом применяют приборы и аппараты как промышленного производства, так и индивидуальные разработки исследователей. Имеется множество методов, зарегистрированных патентов и авторских свидетельств на изобретения и полезные модели для исследования критической частоты слияния мельканий. При этом отсутствует их стандартизация для определения показателя КЧСМ. При определении показателя КЧСМ основным фактором, позволяющим проводить исследование, является отсутствие заболеваний нервной системы (эпилепсия, рассеянный склероз и другие) и зрительного анализатора (отслоение сетчатки и другие). Также к противопоказаниям к применению КЧСМ-теста относятся: боязнь света, обильное слезотечение, острые воспаления в организме, повышенное внутричерепное давление (ВЧД), индивидуальная непереносимость мелькающего света. Поэтому исследование по определению требований, предъявляемых приборам для определения показателя КЧСМ, является актуальным. Необходимо совершенствование нормативной базы, стандартизация методик и приборов для определения КЧСМ. Целью исследования является формулирование требований к приборам и устройствам для определения КЧСМ.</p>
      </abstract>
      <abstract xml:lang="en" lang-variant="translation" lang-source="translator">
        <p>At present, the method of the critical flicker fusion frequency (CFCM) is widely used in the diagnosis and treatment of the human optical system. At present, various instruments and apparatuses, both factory-made and original designs, are widely used in the research of CFCM. There are many methods, registered patents and author’s certificates for inventions and useful models for investigating the critical frequency of flicker fusion. At the same time, there is no standardization for the determination of the CFM index. When determining the indicator of CFCM, the main factor that makes it possible to conduct a study is the absence of diseases of the nervous system (epilepsy, multiple sclerosis and others) and the visual analyzer (retinal detachment and others). Also, contra-indications to the use of the FFMC test include photophobia, lacrimation, acute period of the inflammatory process in the body, increased intracranial pressure, individual intolerance of flashing light. Therefore, the study to determine the requirements for devices to determine the index of CFCM, is relevant. It is necessary to improve the regulatory framework, standardize the methods and instruments for determining CFCM. The aim of the study is to formulate requirements for instruments for determining the critical frequency of flicker fusion.</p>
      </abstract>
      <kwd-group xml:lang="ru">
        <kwd>устройство для определения КЧСМ</kwd>
        <kwd>критическая частота слияния мельканий</kwd>
        <kwd>критическая частота пульсаций света</kwd>
        <kwd>световой стимул</kwd>
        <kwd>светодиод</kwd>
        <kwd>стандарт</kwd>
      </kwd-group>
      <kwd-group xml:lang="en">
        <kwd>device for determining CFCM</kwd>
        <kwd>critical flicker frequency</kwd>
        <kwd>critical frequency of light pulsations</kwd>
        <kwd>light stimulus</kwd>
        <kwd>LED</kwd>
        <kwd>standard</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <ref>
        <note>
          <p>1. Роженцов В.В. Точность измерения критической частоты световых мельканий // Офтальмология. 2013. № 10.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>2. С. 47–49.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>2. Atchison D.A. History and development of wavefront technology / In Yan, W. &amp; Zhao, K. (Eds.). Wavefront and Clinical Visual Optics. People’s Medical Publishing House, Bejing, China, 2011. P. 9–15.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>3. Atchison D.A. Depth of focus of the human eye / In Pallikaris, Ioannis, Plainis, Sotiris, &amp; Charman, W. Neil (Eds.). Presbyopia: Origins, effects and treatment. Slack Incorporated, 2012. 19 p.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>4. Ошурков И. Обоснованный подход к нормативам пульсаций светодиодного освещения // Современная электроника. 2012. № 4. С. 68–71.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>5. ГОСТ IEC 60601-2-51-2011. Изделия медицинские электрические. Часть 2-51. Частные требования безопасности. Введ. 2013-01-01. М.: Стандартинформ, 2013. 103 с.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>6. Волков А.С., Морозова Л.В. КЧСМ как метод психофизиологического исследования зрительного анализатора // Международный студенческий вестник. 2015. № 2–3. С. 310–312.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>7. Лагунов А.Ю., Федин Д.А., Орлов А.В. Полихромный светодиодный блок для измерения КЧСМ // Научные труды SWorld. 2014. Т. 2. № 4. С. 83–89.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>8. Лагунов А.Ю., Федин Д.А., Орлов А.В. Программный комплекс для управления блоком для измерения КЧСМ // Научные труды SWorld. 2014. Т. 2. № 4. С. 89–93.</p>
        </note>
      </ref>
    </ref-list>
  </back>
</article>