Pashkov E.N. 1
Martyushev N.V. 1
Kuznetsov I.V. 1
1 Tomsk Polytechnic University
In article operation features of the liquid autobalancing device are considered. Often the efficiency increase problem solution for automatic balancing at the expense of multitank device use, leads to increase in an ellipsity and eccentrisity an internal surface of the tank. In this work influence of these factors on balancing accuracy was investigated. Work results showed that balancing accuracy doesn’t depend from eccentrisity holders in all cases of imbalance orientation vector. As in a case when the imbalance vector coincides with the line passing through rotor axis, and the internal surface center of a holder, and in a case when the imbalance vector is perpendicular the specified line and in a case when the imbalance vector has the direction, intermediate between the two first cases.